{"product_id":"roche-cobas-h232-cardiovascular-analyser","title":"Roche Cobas H232 Cardiovascular Analyser with Barcode Scanner","description":"\u003ch2\u003eRoche Cobas H232 Key Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003ePortable, easy-to-use analyser with flexible battery operation\u003c\/li\u003e\n\u003cli\u003eRapid and reliable measurement of cardiac markers: Troponin T, NT-pro BNP, D-Dimer\u003c\/li\u003e\n\u003cli\u003eSupports fast diagnosis and treatment of cardiovascular conditions\u003c\/li\u003e\n\u003cli\u003eSuitable for use in clinics, emergency departments, ambulances, or mobile battery-powered operation (e.g., home visits, bedside testing)\u003c\/li\u003e\n\u003cli\u003eReady-to-use test strips, usable immediately after removal from the fridge\u003c\/li\u003e\n\u003cli\u003eNot classified as a system under the RiliBÄK regulation for “point-of-care diagnostics with unit-use reagents”\u003c\/li\u003e\n\u003cli\u003eAdaptable to different workflows and needs through versatile setup functions\u003c\/li\u003e\n\u003cli\u003eIntegrated barcode scanner to reduce input errors (e.g., patient or user IDs)\u003c\/li\u003e\n\u003cli\u003eQuantitative evaluation of immunoassays using gold labelling technology\u003c\/li\u003e\n\u003cli\u003eIntuitive menu guidance requiring minimal training\u003c\/li\u003e\n\u003cli\u003eAccurate results with high correlation to fully automated Roche laboratory methods\u003c\/li\u003e\n\u003cli\u003eEasy network and IT connectivity in the clinic—now also with Wi-Fi\u003c\/li\u003e\n\u003cli\u003eAnalysis possible for: Troponin T, Myoglobin, D-dimer, NT- proBNP, CK- MB\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eMeasurement period of 8-12 minutes\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eSuited for diagnosis and monitoring of various cardial blood markers\u003c\/li\u003e\n\u003cli\u003eVery accurate, lightweight and handy device  \u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eEasy to use, thanks to intuitive user interface\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003ePrecise results with high correlation to fully-automatic Roche lab methods\u003c\/li\u003e\n\u003cli\u003eEconomical, as single tests can be carried out rather than panels\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThe Cobas® h 232 POC system is a portable analyser that can quickly measure cardiac indicators at the point of care. It is perfect for the initial evaluation of patients who may have deep vein thrombosis, heart failure, or acute myocardial infarction.\u003c\/p\u003e\n\u003cp\u003eIt provides precise and dependable results in a matter of minutes, allowing for the objective, laboratory-comparable assessment of a patient's status. In the clinic or emergency room, this facilitates prompt diagnosis and focused treatment choices.\u003c\/p\u003e\n\u003cp\u003eConvenient LAN or Wi-Fi data transmission enables results to be disseminated throughout the medical network for effective workflow management and integrated directly into the electronic patient record.\u003c\/p\u003e\n\u003ch3\u003eAvailable Tests\u003c\/h3\u003e\n\u003ch3\u003eTroponin T\u003c\/h3\u003e\n\u003cp\u003eSupports early diagnosis of acute myocardial infarction (AMI) and identification of patients at increased risk of mortality.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eMeasurement Range:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e40–2000 ng\/l\u003cbr\u003e\u003cb\u003eUnits:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eng\/l, pg\/ml, ng\/ml, μg\/l\u003cbr\u003e\u003cb\u003eMeasurement Time:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e12 minutes\u003c\/p\u003e\n\u003ch3\u003eNT-proBNP\u003c\/h3\u003e\n\u003cp\u003eSupports diagnosis in patients with suspected heart failure, monitoring of patients with compensated left ventricular dysfunction, and risk stratification in acute coronary syndrome.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eMeasurement Range:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e60–9000 pg\/ml\u003cbr\u003e\u003cb\u003eUnits:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003epg\/ml\u003cbr\u003e\u003cb\u003eMeasurement Time:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e12 minutes\u003c\/p\u003e\n\u003ch3\u003eD-Dimer\u003c\/h3\u003e\n\u003cp\u003eUsed to rule out deep vein thrombosis (DVT) and pulmonary embolism (PE).\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eMeasurement Range:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e0.1–4.0 μg\/ml\u003cbr\u003e\u003cb\u003eUnits:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eμg\/ml, ng\/ml, mg\/l, μg\/l\u003cbr\u003e\u003cb\u003eMeasurement Time:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e8 minutes\u003c\/p\u003e\n\u003ch3\u003eMyoglobin\u003c\/h3\u003e\n\u003cp\u003eAn early marker for myocardial injury, supporting the diagnosis of acute coronary syndrome and myocardial infarction.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eMeasurement Range:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e30–700 ng\/ml\u003cbr\u003e\u003cb\u003eUnits:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eng\/ml\u003cbr\u003e\u003cb\u003eMeasurement Time:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e8 minutes\u003c\/p\u003e\n\u003ch3\u003eCK-MB\u003c\/h3\u003e\n\u003cp\u003eSupports the diagnosis of acute coronary syndrome and myocardial infarction, including assessment of reinfarction.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eMeasurement Range:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e1.0–40 ng\/ml\u003cbr\u003e\u003cb\u003eUnits:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eng\/ml\u003cbr\u003e\u003cb\u003eMeasurement Time:\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e12 minutes\u003c\/p\u003e\n\u003ch3\u003eMemory\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e2,000 patient measurements\u003c\/li\u003e\n\u003cli\u003e500 QC measurements\u003c\/li\u003e\n\u003cli\u003e200 IQC measurements\u003c\/li\u003e\n\u003cli\u003ePatient list with 4,000 entries\u003c\/li\u003e\n\u003cli\u003eUser list with 5,000 entries\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInterfaces\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOptional IR printer\u003c\/li\u003e\n\u003cli\u003ePOCT1-A via optional base station\u003c\/li\u003e\n\u003cli\u003ePOCT1-A via Wi-Fi\u003c\/li\u003e\n\u003cli\u003eQR code support\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eSafety\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eComprehensive safety features are provided by the Cobas® H 232 to safeguard private patient information and guarantee proper use.\u003c\/p\u003e\n\u003cp\u003eEntering a distinct operator ID guarantees that all activities can be unmistakably linked to a particular user and stops unwanted access. The system ensures thorough documentation of test results by logging patient and operator IDs, which is essential for traceability and quality control. In order to guarantee the continuous dependability of measurement data, the gadget can also automatically lock if specified quality control procedures are not followed.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eControl and Traceability\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe system has Wi-Fi and a QR code feature for safe and effective data management, which minimises input errors and streamlines workflows.\u003c\/p\u003e\n\u003cp\u003eBy integrating with the Cobas® Infinity POC platform, the laboratory may perform central quality control by automatically documenting all pertinent activities, such as accreditation, user authorisation, and device status.\u003c\/p\u003e\n\u003cp\u003eAdditionally, only allowed and trained individuals may access the system thanks to automatic recertification via the linked Learning Management System (LMS), which maximises safety and traceability in routine diagnostic practice.\u003c\/p\u003e\n\u003ch3\u003eOther Technical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eData transfer: Wi-Fi, QR code, Ethernet, USB (HBU), IR\u003c\/li\u003e\n\u003cli\u003eBattery operation: approx. 10 measurements per charge\u003c\/li\u003e\n\u003cli\u003eInput: 100–240 V AC (±10 %), 50–60 Hz, 400 mA\u003c\/li\u003e\n\u003cli\u003eOutput: 7.5 V DC \/ 1.7 A\u003c\/li\u003e\n\u003cli\u003eProtection class: III\u003c\/li\u003e\n\u003cli\u003eStart-up time: \u0026lt;20 seconds from cold start; 1 second from standby\u003c\/li\u003e\n\u003cli\u003eAutomatic shutdown feature included\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFor detecting the following, depending on the test strip:\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eAcute coronary syndrome or acute myocardial infarction\u003c\/li\u003e\n\u003cli\u003eHeart insufficiency\u003c\/li\u003e\n\u003cli\u003eRisk stratification with an unstable angina pectoris\u003c\/li\u003e\n\u003cli\u003eRisk stratification with acute coronary syndrome\u003c\/li\u003e\n\u003cli\u003eEvidence of a reinfarction\u003c\/li\u003e\n\u003cli\u003eMonitoring reperfusion with thrombolytic therapy\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eTechnical Details\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eLess than 20 seconds of warm-up time with a new start\u003c\/li\u003e\n\u003cli\u003eAutomatic switchoff (after 1 to 60 minutes, programmable)\u003c\/li\u003e\n\u003cli\u003eDimensions: 27.5 x 10.2 x 5x5 cm\u003c\/li\u003e\n\u003cli\u003eWeight: approx. 650 g\u003c\/li\u003e\n\u003cli\u003eSample used is heparinised venous whole blood\u003c\/li\u003e\n\u003cli\u003eSample amount: 150 µL\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCobas H232\u003c\/strong\u003e can be used with reagents that are taken directly from the fridge; thus eliminating the waiting period for warming them up to room temperature.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Roche Diagnostics","offers":[{"title":"Default Title","offer_id":48209723424953,"sku":"Art. no.: 128901","price":0.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0650\/4801\/9129\/files\/Cobas_H232_2.png?v=1784371719","url":"https:\/\/poc-diagnostics.co.uk\/products\/roche-cobas-h232-cardiovascular-analyser","provider":"POC Diagnostics","version":"1.0","type":"link"}