{"product_id":"roche-diagnostics-cobas®-click","title":"Roche Diagnostics cobas® click","description":"\u003cp class=\"prx-product-header-info-bottom__short-facts-title\"\u003eThe product at a glance\u003c\/p\u003e\n\u003cul class=\"prx-product-header-info-bottom__short-facts-list\"\u003e\n\u003cli\u003eRapid test results from as little as 4 minutes\u003c\/li\u003e\n\u003cli\u003eMinimally invasive with only 2.5–17 µl capillary blood\u003c\/li\u003e\n\u003cli\u003eCapacitive touchscreen and integrated barcode scanner\u003c\/li\u003e\n\u003cli\u003eMaintenance-free system with room temperature-stable test discs\u003c\/li\u003e\n\u003cli\u003eConnectivity: USB, LAN, WLAN with secure data transmission\u003c\/li\u003e\n\u003cli\u003eStorage for up to 5,000 results and export function\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"prx-product-description-section__headline\"\u003eProduct Information\u003c\/div\u003e\n\u003cdiv class=\"prx-product-description-section__headline\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"prx-product-description-section__content\"\u003e\n\u003cp\u003eProduct Description\u003c\/p\u003e\n\u003cp\u003eA point-of-care option for near-patient HbA1c, lipid, and CRP testing is the Cobas® Click system. Its user-friendly interface and cutting-edge test disc technology allow for quick testing in clinics, pharmacies, and medical offices.\u003c\/p\u003e\n\u003cp\u003eDuplicate tests can be finished in 15 minutes, while individual test results are accessible in 4-6 minutes. This eliminates the need for long wait times when incorporating test results into clinical decision-making.\u003c\/p\u003e\n\u003cp\u003eThe technology combines practical ease of use with excellent accuracy and precision. To reduce interference, the microfluidic test discs have built-in diluents. Triglyceride interference is detected and corrected by a fail-safe system during lipid testing. The purpose of the HbA1c test is to lessen the impact of haemoglobin variations.\u003c\/p\u003e\n\u003cp\u003eCapillary blood samples as little as 2.5 µl are used for testing, enabling direct sampling with a minimal blood volume. Because to its straightforward click closure, the maintenance-free test discs are easy to handle and can be kept at room temperature.\u003c\/p\u003e\n\u003cp\u003eWhile the embedded barcode scanner makes it easier to identify patients and tests, integrated WLAN, LAN, and USB interfaces provide networking and data management. Up to 5,000 patient results can be stored in the system, and data can be exported for effective documentation and traceability.\u003c\/p\u003e\n\u003cp\u003eSimple operation is supported by a capacitive touchscreen and an easy-to-use interface, and the Cobas® Click system's sturdy architecture makes it possible to incorporate it into current processes. When combined, the system's data management, networking, and testing features offer a workable option for point-of-care diagnostics.\u003c\/p\u003e\n\u003cp\u003eSpecifications\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eProduct: cobas® click point-of-care system\u003c\/li\u003e\n\u003cli\u003eApplication area: Quantitative analysis of clinical-chemical and immunological tests (HbA1c, lipids, CRP)\u003c\/li\u003e\n\u003cli\u003eSample material:\n\u003col\u003e\n\u003cli\u003eCapillary blood\u003c\/li\u003e\n\u003cli\u003eVenous EDTA whole blood\u003c\/li\u003e\n\u003cli\u003eSerum (for CRP)\u003c\/li\u003e\n\u003cli\u003ePlasma (EDTA and lithium heparin, for CRP)\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003c\/li\u003e\n\u003cli\u003eSample volume:\n\u003col\u003e\n\u003cli\u003eHbA1c: 2.5 µl\u003c\/li\u003e\n\u003cli\u003eLipids: 17 µl\u003c\/li\u003e\n\u003cli\u003eCRP: 13 µl\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003c\/li\u003e\n\u003cli\u003eMeasurement ranges:\n\u003col\u003e\n\u003cli\u003eHbA1c: 20–130 mmol\/mol (IFCC) or 4–14 % (DCCT\/NGSP)\u003c\/li\u003e\n\u003cli\u003eLipids:\n\u003cul\u003e\n\u003cli\u003eTotal cholesterol (TC): 50–500 mg\/dl\u003c\/li\u003e\n\u003cli\u003eTriglycerides (TG): 45–650 mg\/dl\u003c\/li\u003e\n\u003cli\u003eHDL cholesterol: 15–100 mg\/dl\u003c\/li\u003e\n\u003cli\u003eLDL cholesterol: (calculated from TC, HDL, TG)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eCRP: 3.0–400 mg\/l or 0.30–40.0 mg\/dl\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003c\/li\u003e\n\u003cli\u003eMeasurement time:\n\u003col\u003e\n\u003cli\u003eHbA1c: \u0026lt; 6 minutes\u003c\/li\u003e\n\u003cli\u003eLipids: \u0026lt; 6 minutes\u003c\/li\u003e\n\u003cli\u003eCRP: \u0026lt; 4 minutes\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003c\/li\u003e\n\u003cli\u003eStorage capacity:\n\u003col\u003e\n\u003cli\u003ePatient results: up to 5,000\u003c\/li\u003e\n\u003cli\u003eUser information: up to 3,000\u003c\/li\u003e\n\u003cli\u003ePatient data: up to 3,000\u003c\/li\u003e\n\u003cli\u003eQuality control results: up to 500\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003c\/li\u003e\n\u003cli\u003eDevice interfaces:\n\u003col\u003e\n\u003cli\u003eUSB (PC connection)\u003c\/li\u003e\n\u003cli\u003eUSB (for USB stick or printer)\u003c\/li\u003e\n\u003cli\u003eRJ45 LAN port\u003c\/li\u003e\n\u003cli\u003eIntegrated WLAN module\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003c\/li\u003e\n\u003cli\u003eDisplay: Capacitive touchscreen\u003c\/li\u003e\n\u003cli\u003eDimensions: 135 × 184 × 234 mm (W × H × D)\u003c\/li\u003e\n\u003cli\u003eWeight: 2.0 kg (without power supply)\u003c\/li\u003e\n\u003cli\u003eOperating temperature: 15–32 °C\u003c\/li\u003e\n\u003cli\u003eStorage temperature of test discs: 2–30 °C\u003c\/li\u003e\n\u003cli\u003eRelative humidity: 10–85 % (non-condensing)\u003c\/li\u003e\n\u003cli\u003eMaximum operating altitude: 3,000 m\u003c\/li\u003e\n\u003cli\u003eAutomatic functions:\n\u003col\u003e\n\u003cli\u003eProgrammable shutdown (1–999 minutes)\u003c\/li\u003e\n\u003cli\u003eProgrammable automatic logout (1–60 minutes)\u003c\/li\u003e\n\u003cli\u003eProgrammable bypass of lock tests (1–9 tests)\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003c\/li\u003e\n\u003cli\u003eMaintenance requirements: No maintenance except cleaning and disinfection\u003c\/li\u003e\n\u003cli\u003eStandards and guidelines:\n\u003col\u003e\n\u003cli\u003eComplies with Regulation (EU) 2017\/746 on in vitro diagnostics\u003c\/li\u003e\n\u003cli\u003eComplies with IEC 61326-2-6:2020 for electromagnetic compatibility\u003c\/li\u003e\n\u003cli\u003eConformity with Directive 2011\/65\/EU (RoHS)\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003c\/li\u003e\n\u003cli\u003eScope of delivery:\n\u003col\u003e\n\u003cli\u003ecobas® click device\u003c\/li\u003e\n\u003cli\u003eUser documentation\u003c\/li\u003e\n\u003cli\u003ePower supply and mains cable\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eApplication Scope\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDiabetology\n\u003col\u003e\n\u003cli\u003eLong-term monitoring of glycaemic control through precise HbA1c determination\u003c\/li\u003e\n\u003cli\u003eSupport in therapy adjustment and optimisation\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003c\/li\u003e\n\u003cli\u003eCardiology\n\u003col\u003e\n\u003cli\u003eLipid profile analysis for assessment of cardiovascular risk\u003c\/li\u003e\n\u003cli\u003eRapid availability of cholesterol and triglyceride values for risk evaluation\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003c\/li\u003e\n\u003cli\u003eInternal Medicine \/ General Practice\n\u003col\u003e\n\u003cli\u003eDifferential diagnosis of inflammatory processes through CRP measurement\u003c\/li\u003e\n\u003cli\u003eSupport of antibiotic management through reliable CRP values\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003c\/li\u003e\n\u003cli\u003eEmergency Medicine\n\u003col\u003e\n\u003cli\u003eTimely decision-making in critically ill patients through rapid laboratory results\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003c\/li\u003e\n\u003cli\u003eOutpatient Care and Practice Laboratory\n\u003col\u003e\n\u003cli\u003eEfficient patient care through point-of-care tests without delays from external laboratories\u003c\/li\u003e\n\u003cli\u003eImprovement of workflow and documentation processes through integrated connectivity\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003c\/li\u003e\n\u003cli\u003ePharmaceutical Counselling in Pharmacies\n\u003col\u003e\n\u003cli\u003eMonitoring of at-risk patients as part of health checks\u003c\/li\u003e\n\u003cli\u003eSupport in therapy recommendations based on valid test results\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eTechnical Specifications\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDimensions: 135 × 184 × 234 mm (W × H × D)\u003c\/li\u003e\n\u003cli\u003eWeight: 2.0 kg (without power supply)\u003c\/li\u003e\n\u003cli\u003eDisplay: Capacitive touchscreen\u003c\/li\u003e\n\u003cli\u003eMemory:\n\u003cul\u003e\n\u003cli\u003e5,000 patient results\u003c\/li\u003e\n\u003cli\u003e3,000 patient information records\u003c\/li\u003e\n\u003cli\u003e3,000 user information records\u003c\/li\u003e\n\u003cli\u003e500 quality control results\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eInterfaces: USB (PC), USB (USB stick\/printer), RJ45 LAN, integrated WLAN\u003c\/li\u003e\n\u003cli\u003eMeasurement time:\n\u003cul\u003e\n\u003cli\u003eHbA1c: \u0026lt; 6 minutes\u003c\/li\u003e\n\u003cli\u003eLipids: \u0026lt; 6 minutes\u003c\/li\u003e\n\u003cli\u003eCRP: \u0026lt; 4 minutes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eSample volume:\n\u003cul\u003e\n\u003cli\u003eHbA1c: 2.5 µl\u003c\/li\u003e\n\u003cli\u003eLipids: 17 µl\u003c\/li\u003e\n\u003cli\u003eCRP: 13 µl\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eStorage temperature of test discs: 2–30 °C\u003c\/li\u003e\n\u003cli\u003eOperating temperature of device: 15–32 °C\u003c\/li\u003e\n\u003cli\u003eRelative humidity: 10–85 % (non-condensing)\u003c\/li\u003e\n\u003cli\u003eMaximum operating altitude: 3,000 m\u003c\/li\u003e\n\u003cli\u003eNoise emission: max. 65 dB (A)\u003c\/li\u003e\n\u003cli\u003eAutomatic functions: shutdown (programmable 1–999 min), automatic logout (programmable 1–60 min), bypass lock tests (programmable 1–9 tests)\u003c\/li\u003e\n\u003cli\u003eMaintenance: None required except cleaning and disinfection\u003c\/li\u003e\n\u003cli\u003ePower supply: 12 V DC\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003cstrong\u003eStandards: Complies with IEC 61326-2-6:2020 (EMC), Regulation (EU) 2017\/746, RoHS Directive 2011\/65\/EU\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eUsage Operation\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTurn on the device and wait until the main menu is displayed after the self-check.\u003c\/li\u003e\n\u003cli\u003eEnsure that the date and time are set correctly to guarantee precise documentation.\u003c\/li\u003e\n\u003cli\u003eSelect the “Patient test” option in the main menu and enter the patient ID by scanning or manual input.\u003c\/li\u003e\n\u003cli\u003eOpen the test disc packaging and remove the disc without touching the test surface.\u003c\/li\u003e\n\u003cli\u003ePrepare the capillary blood collection:\n\u003col\u003e\n\u003cli\u003eAsk the patient to wash their hands thoroughly with soap and warm water and dry them to promote blood circulation.\u003c\/li\u003e\n\u003cli\u003eDisinfect the puncture site with an alcohol swab and allow it to dry.\u003c\/li\u003e\n\u003cli\u003eUse a sterile lancet with the recommended puncture depth (e.g., 3 for lipid tests).\u003c\/li\u003e\n\u003cli\u003ePuncture the side of the fingertip and remove the first drop of blood to avoid contamination.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003c\/li\u003e\n\u003cli\u003eCarefully apply the blood volume to the sample inlet of the test disc until the transparent spot is completely covered.\u003c\/li\u003e\n\u003cli\u003eClose the disc cover with a “click”. Once closed, reopening is not possible.\u003c\/li\u003e\n\u003cli\u003eImmediately insert the test disc into the device and close the device cover to start the automatic measurement.\u003c\/li\u003e\n\u003cli\u003eWait for the result, which will be displayed after approximately 4 to 6 minutes.\u003c\/li\u003e\n\u003cli\u003eConfirm the completion of the test via the display and dispose of the disc properly.\u003c\/li\u003e\n\u003cli\u003eUse the integrated connectivity options for easy data management and documentation in the daily work in a medical practice.\u003c\/li\u003e\n\u003cli\u003ePerform regular cleaning and disinfection of the device to ensure operational safety; maintenance is not required.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eScope of Delivery\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e1× cobas® click device\u003c\/li\u003e\n\u003cli\u003e1× power supply unit\u003c\/li\u003e\n\u003cli\u003e1× mains power cable\u003c\/li\u003e\n\u003cli\u003e1× user documentation (operating instructions)\u003c\/li\u003e\n\u003cli\u003eConsumables are not included and are available separately:\n\u003col\u003e\n\u003cli\u003ecobas® HbA1c test discs Gen. 2 (20 pieces per pack)\u003c\/li\u003e\n\u003cli\u003ecobas® Lipid Panel test discs Gen. 2 (20 pieces per pack)\u003c\/li\u003e\n\u003cli\u003ecobas® CRP test discs Gen. 2 (20 pieces per pack)\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003c\/li\u003e\n\u003cli\u003eOptional accessories and controls are also available separately for quality assurance and optimal use\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Roche Diagnostics","offers":[{"title":"Default Title","offer_id":67778933457081,"sku":"Art. no.: 152738","price":0.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0650\/4801\/9129\/files\/82691-152738-cobas-click-roche2.webp?v=1792403475","url":"https:\/\/poc-diagnostics.co.uk\/products\/roche-diagnostics-cobas%c2%ae-click","provider":"POC Diagnostics","version":"1.0","type":"link"}