Product overview For detecting risk of preterm labour Detects the protein foetal fibronectin (fFN) Sample material: cervical vaginal secretion Simple interpretation after only 10 minutes Sensitivity: 99%; Specificity: 99.9% Guaranteed usable: 02.06.2027 TODA fFN DIAG® from Toda Pharma...
Availability: In stock
Fast Results

Rapid testing support.

Professional Use

Designed for clinical settings.

Secure Ordering

Safe online checkout.

Technical Support

Support available when needed.

Why Choose This Product?

Result in 10 minutes

High Anlytical Sensitivity

Support Rapid AMI Assessment

Easy point-of-care workflow

Suitable for Clinical settings

No Complex Laboratory Equipment Required

Clinical Applications

Suitable for professional diagnostic use across clinical and healthcare environments.

Emergency Departments

Enables immediate triage and rapid decision-making for patients presenting with acute chest pain.

Urgent care Centers

Provides on-the-spot evaluation to determine if emergency hospital transfer is clinically necessary.

Cardiology Clinics

Supports outpatient cardiovascular assessment and rapid exclusion of ongoing myocardial injury.

Hospitals

Allows for rapid bedside testing in intensive care units and coronary care wards.

Ambulance Services

Equips paramedics with the ability to assess Troponin levels during patient transit to guide destination protocols.

Diagnostic Laboratories

Serves as an immediate, reliable qualitative backup for central laboratory immunoassay analyzers.

How the Troponin Rapid Test Works

1

Collect Sample

Obtain Whole Blood, Serum, or Plasma

2

Apply Sample

Add sample & buffer to the Test Cassette

3

Wait

Allow reaction to process for 10 Minutes

4

Interpret

Read visual color bands per the IFU

Clinical Conditions This Test Supports

This section helps explain the professional clinical use cases supported by this diagnostic product.

Acute Myocardial Infarction (AMI)

Chest Pain Assessment

Cardiac Injury Evaluation

Emergency Cardiac Screening

Early Cardiac Risk Assessment

Troponin vs CK-MB vs Myoglobin

In clinical cardiology, mapping the timeline of myocardial necrosis relies on understanding the unique kinetic profiles of various cardiac biomarkers. Myoglobin is highly sensitive to muscle damage and rises earliest, making it valuable for early exclusion. Troponin I is mapped to cardiac muscle damage and remains elevated longer. CK-MB clears more rapidly and can help identify recurrent infarctions.

Marker Time to Rise Peak Time Return to Normal Clinical Use
Troponin I 4-6 hours 12-24 hours 3-10 days Definitive AMI diagnosis
CK-MB 3-6 hours 12-24 hours 48-72 hours Detecting re-infarction
Myoglobin 1-3 hours 6-9 hours 24-36 hours Early exclusion of AMI

Comprehensive Product Information

Key Features

  • High analytical sensitivity.
  • Rapid results within 10 minutes.
  • Easy to interpret visual color bands.
  • No specialized equipment required.

Intended Use & Clinical Apps

Intended for use in medical facilities as an aid in the rapid diagnosis of acute myocardial infarction (AMI).

Emergency Rooms Urgent Care Paramedic/Ambulance Cardiology Clinics

Technical Specifications

Specimen Whole Blood / Serum / Plasma
Time to Result 10 Minutes
Cut-off 0.5 ng/mL
Accuracy 98.9%

Storage

Store sealed pouch at 2°C to 30°C. DO NOT FREEZE. Use within expiration date.

Contents

  • 25 Test Cassettes
  • 25 Disposable Droppers
  • 1 Buffer Solution
  • 1 Package Insert
Healgen Logo

About Healgen

Healgen Scientific is a globally recognized manufacturer of specialized in vitro diagnostic tests. Renowned for advanced diagnostic expertise and product quality, Healgen operates under strict ISO quality standards and is trusted by healthcare professionals worldwide.

View All Healgen Products

Product FAQs

Troponin I is a cardiac biomarker commonly used to support diagnosis of myocardial injury and acute myocardial infarction.

Troponin I is a cardiac biomarker commonly used to support diagnosis of myocardial injury and acute myocardial infarction.

Troponin I is a cardiac biomarker commonly used to support diagnosis of myocardial injury and acute myocardial infarction.

Troponin I is a cardiac biomarker commonly used to support diagnosis of myocardial injury and acute myocardial infarction.

Troponin I is a cardiac biomarker commonly used to support diagnosis of myocardial injury and acute myocardial infarction.

Troponin I is a cardiac biomarker commonly used to support diagnosis of myocardial injury and acute myocardial infarction.

Professional Troponin I Rapid Testing Solutions

What Is Troponin Testing?

A Troponin Test measures the levels of troponin proteins—specifically Troponin I and Troponin T—in the bloodstream. These regulatory proteins are integral to cardiac muscle contraction and are virtually absent in the blood of healthy individuals.

Why Troponin Is Important In Cardiology

In the realm of Cardiac Marker Testing, troponin is recognized as a gold standard due to its cardiac specificity. An elevation in Troponin I can support accurate AMI diagnosis and clinical evaluation.

Point-of-Care Cardiac Testing & Emergency Diagnostic Applications

Point-of-Care Testing allows healthcare professionals to conduct rapid diagnostic testing closer to the patient. This supports faster triage decisions and more efficient emergency workflows.

Benefits Of Rapid Troponin Testing

Integrating point-of-care Healthcare Diagnostics offers profound clinical benefits:

  • Immediate Triage: Faster confirmation of Acute Myocardial Infarction Detection allows for earlier administration of reperfusion therapy.
  • Resource Optimization: Rapidly ruling out AMI in low-risk chest pain patients frees up critical emergency department beds.
  • Procedural Simplicity: The lateral flow cassette format requires minimal training and completely negates the need for bulky laboratory analyzers.

Cardiac Biomarkers Explained in Clinical Diagnostics

As a provider of premium Clinical Diagnostics, we emphasize that while the Troponin I cassette is highly specific, it is often utilized in conjunction with other rapid tests to form a complete kinetic profile of the cardiac event. Understanding the temporal release patterns of these biomarkers allows healthcare professionals to accurately pinpoint the onset of the infarction and monitor the patient's recovery trajectory reliably.

CE-Marked Products
shield-check-line Secure Online Ordering
Healthcare Focused Supplier
Worldwide Shipping
Technical Support Available